The MP120-24 was implemented in a medical monitoring system in 2015.
Telcordia sr 332 handbook full#
The MP120’s specification shows an MTBF spec of 200k Hours at 25☌ under full load. 5V STDBY can supply 0.5A with remote control connection. The input voltage is 85-264Vac, and main output voltage is 12Vdc, 19Vdc, 24Vdc, 28Vdc and 48Vdc respectively.
Telcordia sr 332 handbook series#
The MP120 series is a 2” x 4” x 1.35” 120W/150W convection/forced air cooled open frame medical power supply has been in production since 2015. Test Case: Verifying the MTBF calculation for the MP120 Series with DMTBF K- Boltzmann Constant, equals to 8.617E-05 eV/KĪfp-High temperature acceleration factor Arrhenius modelĪft-Power acceleration factor =60min/(Ton+Toff), Common pick: 2 Through DMTBF verification, the reliability of medical power supplies can be predicted, verified and even improved, which ensures customer satisfaction through improved competitiveness of a medical device as well as a reduction in overall quality risk.Įa- Activation Energy, Electronics, Ea=0.3-1.0eV.
Telcordia sr 332 handbook verification#
To provide the accurate verification of the calculated MTBF, DMTBF must be used. These issues-poor workmanship, shoddy components and design flaws-are the overlooked blind spots in the calculation of MTBF. This makes DMTBF the most strict and effective verification for a product’s MTBF prediction. DMTBF’s verification is at the beginning stage of the bathtub curve.Įarly failure is mainly caused by poor workmanship, shoddy components and even design flaws. There is a high failure rate during the beginning phase and final phase of the power supply’s service life. The Bathtub Curve (Figure 1) is a well-known failure rate over time curve for power supplies. DMTBF is an effective way to demonstrate and verify a MTBF calculation. Under a controlled high-stress environment (including temperature, humidity, electrical, mechanical, etc.) extended life testing is used to accelerate deterioration to predict MTBF and validate normal power supply operation in a short period of time. MIL-HDBK-217F Notice 2 is the Reliability Prediction of Electronic Equipment in the US Military Handbook, and TELCORDIA SR/TR-332(Bellcore) is the generally accepted Reliability Prediction for commercial electronics.ĭMTBF (Demonstrated Mean Time Between Failures) is a method used to test reliability.
Telcordia sr 332 handbook plus#
Because of this dedicated supply chain management, many products will work well beyond the hours for which they are rated.Ĭurrently, the most common calculation method for MTBF is Part Count plus Stress Analysis following guidelines such as MIL-HDBK-217F Notice 2 and TELCORDIA SR/TR-332(Bellcore). Using trusted component suppliers ensures that the MTBF is the minimum expectation for all Phasium products.
These include resistors and electrolytic capacitors from known, qualified suppliers in Japan and the United States as well as silicon from similar known, trusted vendors. In order to achieve a high MTBF rating and a long service life, all Phasium medical power supplies are specifically designed with high-quality components. The calculated MTBF is used to identify potential design flaws and to improve power supply design via reliability and field life.
The MTBF factor is calculated and tested based on assumptions such as an electrical component’s stress factor under known circumstances. MTBF (Mean Time Between Failures) is a well-accepted method for measuring power supply reliability. Medical Power Supply Reliability Demonstration: MTBF and DMTBF